english
中文
Hotline: 010-87695555 / 87690555
Home About us Products
Case Message After-sale Download Contact us
Notify
  • Jinghua Reminder: Equal quality to price, equal price to service, genuine goods at a reasonable price is the hard truth!!

    The products produced by our company include: building lighting series, including: organic glass lighting cover, fiberglass lighting cover, 

    polycarbonate PC endurance board lighting cover, sunlight board lighting shed, greenhouse greenhouse, bicycle shed, explosion-proof skylight, explosion-proof skylight, 

    explosion-proof skylight, pressure relief skylight, pressure relief ventilation skylight, and explosion-proof door and window series. 

    The fiberglass series includes the installation and construction of various series of products such as fiberglass cooling towers, fiberglass water tanks, fiberglass fume hoods, 

    fiberglass ventilation fans, fiberglass ventilation ducts, fiberglass anti-corrosion and waterproof engineering, as well as clean workshops, fiberglass relief craft products, etc. 

    The product has been installed and used in more than 20 provinces, cities, autonomous regions, and foreign aid projects nationwide.


京华城铭
location:Home>京华城铭
Detailed specification parameter table for fiberglass axial fan
Time:2024-01-18 vesits:276
FRP axial fan navigation >>>
  T35-11 FRP axial fan >>>  FZ50 FRP axial fan >>>
 BT35-11 explosion-proof flame retardant axial flow fan >>> FT401 FRP axial fan >>>
 BZ-T30K4-11 FRP axial fan >>> BHW FRP vertical axial fan >>>
 GD30K2-12 FRP axial fan >>>
 T35-11 FRP axial fan
T35-11 FRP axial fan series and installation dimension drawing
 T35-11 FRP axial fan performance table

demo_01(21).jpg

 T35-11 FRP axial fan shape and installation size table

demo_01(22).jpg

demo_01(23).jpg

 Maintenance of axial flow fans:

1. Before installation, check in detail whether the fan is damaged or deformed due to packaging and transportation, and it can only be installed after it is properly repaired. During installation, it is necessary to check whether the connecting parts are loose, and the gap between the blades and the hair dryer should be uniform and should not be touched.

2. The weight of the pipe connecting the air outlet should not be borne by the fan duct, and additional support should be added during installation.

3. An air collector must be installed at the inlet end of the axial flow fan, and a protective wire mesh must be installed.

4. The base of the fan must be naturally connected with the foundation plane, and the bolts shall not be knocked to force the connection to prevent the base from deforming. When installing, the base should be calibrated with a level, padded to maintain its horizontal position, and then the anchor bolts should be tightened.

5. The axial flow fan is not allowed to be hoisted and used, and after the installation of the wire, it must be tested first.

6. After the ventilator has not been used for a long time, when it is reused, it is necessary to check whether the connecting parts are reliable and reliable, and can only be officially used after trial operation.

7. After the fan is officially put into operation, check whether the screws are loose and whether the wire skin is damaged once a year, and repair it according to its specific situation.

8. Always pay attention to whether there is abnormal noise in the operation of the fan, whether the vibration increases, and check and repair it in time.

  BT35-11 explosion-proof flame retardant FRP axial fan

demo_01(24).jpg

  BZ-T30K4-11 FRP axial fan
BZ-T30K4-11 FRP axial fan performance specification table

demo_01(25).jpg

BZ-T30K4-11 FRP axial fan shape and installation dimension drawing
BZ-T30K4-11 FRP axial fan shape and installation size

demo_01(26).jpg

  GD30K2-12 FRP axial fan
 GD30K2-12 FRP axial fan size table
 GD30K2-12 FRP axial fan size table

demo_01(27).jpg

 GD30K2-12 FRP Axial Fan Fan Performance Table

demo_01(28).jpg

  FZ50 FRP axial fan
FZ50 No.12 FRP axial fan performance and selection table

demo_01(29).jpg

FZ50 No.16 FRP axial fan performance and options table

demo_01(30).jpg

FZ50 No.20 FRP axial fan performance and selection table

demo_01(31).jpg

 FZ50A FRP axial fan performance profile installation drawing
FZ50A No12, 16, 20 FRP axial fan shape and installation size table

demo_01(32).jpg

  FT401 FRP axial fan
The performance and selection table of FT401 axial flow fan refers to the air performance under standard conditions (temperature 20 degrees, relative humidity 50%, atmospheric pressure 760mmHg, medium gravity 1.2Kg/m3). When the impeller speed changes, the performance of the fan can be converted according to the relevant formula.
 FT401 FRP axial fan performance and selection table
 FT401 FRP axial fan shape and installation dimension drawing
 FT401 FRP axial fan shape and installation size table
 BHW type FRP vertical axial flow fan
 BHW FRP vertical axial flow fan shape and installation dimension drawing
 BHW FRP vertical axial flow fan performance selection table
 BHW FRP vertical axial flow fan shape and installation size table
zlfj-13.jpg


Home
Product
Contact
WeChat
TEL:010-87695555 / 87690555
EMAIL:jhfrp@163.com
ADDRESS:Room 1292, North Bank, Building 8, 4th Floor, Creative Life Park, No. 1292, Courtyard A1, Jianguo Road, Chaoyang District, Beijing 068
Total visits to this website
Copyright © 2023 Jinghua Chengming All Rights Reserved. 冀公网安备13112202000235号