本公司生产的产品有:建筑采光系列有:有机玻璃采光罩、玻璃钢采光罩、聚碳酸酯PC耐力板采光罩、阳光板采光棚、温室大棚、自行车棚,防爆天窗,抗爆天窗,泄爆天窗、泄压天窗,泄爆泄压通风天窗,泄爆门窗系列。玻璃钢系列有:玻璃钢冷却塔、玻璃钢水箱、玻璃钢通风柜、玻璃钢通风机、玻璃钢通风管道、玻璃钢防腐防水工程施工以及洁净厂房、玻璃钢浮雕工艺制品等多种系列产品的安装与施工。产品已安装使用在全国20多个省、市、自治区以及援外工程上。
FRP-glass fiber reinforced plastic cooling tower, also known as cooling water tower, is commonly used in industrial and civil cooling facilities. It is basically divided into two categories in terms of structural performance: 1. Counterflow FRP cooling tower (round, square) 2. Cross-flow fiberglass cooling tower (square) Structural features of fiberglass cooling tower: ★The outer protection structure of the tower body is made of high-quality fiberglass, and the surface is made of weather-resistant and UV-resistant gelcoat resin. It has the characteristics of aging resistance, corrosion resistance, bright and smooth surface, and non-fading. The color can be made according to user needs. ★The fan adopts a special aluminum alloy fan, which has the characteristics of reasonable tower crane matching, large air volume, low noise, high efficiency, smooth operation, uniform wind speed, and no slipping when exposed to water. ★The motor adopts a special motor for cooling towers, which has the advantages of energy saving and high efficiency. The reducer adopts the latest designed special reducer for cooling towers, which has smooth operation, high efficiency, low noise, low temperature rise and long life. ★The filler is a new type of high-efficiency filler, which is modified to be temperature-resistant and has certain hydrophilicity. It can redistribute water evenly and form a good water film. The structure is specially designed to have low wind resistance, smooth airflow, good heat dissipation effect, and good water collection function. ★The steel bracket support structure adopts advanced galvanized anti-corrosion technology, which is strong, durable and anti-corrosion. ★The combinable installation feature allows the water treatment volume to be doubled while occupying a small land area. ★It has beautiful appearance and is very coordinated with the building. It is especially suitable for the air cooling system of high-end buildings such as hotels and hotels. ★The water-ponding tower chassis has a water tank that can replace a small concrete pool. It has a large water storage capacity and is equipped with manual and automatic water supply devices, sewage discharge and overflow pipes, etc., which can save a lot of pool costs. It is a novel series of products in China at present. | ||||
Counterflow FRP cooling tower: Definition of terms: A cooling tower in which water flows from top to bottom and air flows from bottom to top in the packing in the tower. The two flow in opposite directions. Tower body shape: From the shape of the tower body, counterflow cooling towers can be divided into two types: circular counterflow type and square counterflow type. The square tower occupies a relatively small area. Specifications and models: Circular counterflow cooling towers can be divided into three types: low noise, ultra-low noise, and industrial type, with models ranging from 12T to 1000T. DBNL3: low-noise fiberglass counterflow cooling tower; CDBNL3: Ultra-low noise fiberglass counterflow cooling tower; GBNL3: Industrial medium and high temperature fiberglass counterflow cooling tower. Square counterflow cooling towers can be divided into many specifications and models: standard type, medium temperature type, high temperature type and square counterflow energy-saving type. Standard type: FBL: standard ordinary type; FBLD: Standard multi-wind model; FBLS: standard low noise; FBLSD: standard low noise multi-wind model; FBLSS: Standard ultra-low noise type; FBLSSD: Standard ultra-low noise multi-wind model; FBLW: Standard chassis-less type; FBLDW: Standard multi-fan without chassis type. Medium temperature type: FBL(Ⅱ): medium temperature ordinary type; FBL(Ⅱ)D: medium temperature and high wind model; FBLS(Ⅱ): medium temperature and low noise type; FBLS(Ⅱ)D: medium temperature, low noise and high wind model; FBLSS(Ⅱ)D: Medium temperature ultra-low noise type; FBLSS(Ⅱ)D: Medium temperature, ultra-low noise, multi-wind model; FBL(Ⅱ)W: medium temperature without chassis type; FBL(Ⅱ)DW: medium temperature multi-fan without chassis type. High temperature type: FGBL: high temperature ordinary type; FGBLD: high temperature and windy model; FGBLW: high temperature without chassis type; FGBLDW: High-temperature multi-fan without chassis type. Energy-efficient: DFNL: Square counter-flow low temperature drop type; GFNL: square counter-flow medium and high temperature drop type; CDFNL: Square counter-flow ultra-low noise and low temperature drop type. Later models include DP for shallow water dish type and GP for deep water dish type. Performance introduction: The water temperature drop of low-noise and ultra-low-noise towers is generally 3-8°C, which is suitable for cooling equipment such as air conditioning and refrigeration. The noise value of the ultra-low noise tower is approximately 5dB lower than the standard point of the low-noise tower, making it suitable for places with stricter noise requirements. The industrial type is a medium-high temperature tower. The water temperature drop is generally 10-25°C. This type increases a series of measures such as tower diameter, air volume and pressure, power, and packing height. It is suitable for cooling industrial water with high water temperature drop. Precautions for selection and use: 1. When selecting, you should know the water volume, inlet water temperature, outlet water temperature and design wet bulb temperature, and determine the model based on the thermal performance curve. 2. In areas where the average temperature in the coldest month is -10°C, please indicate this when ordering so that anti-icing measures can be taken. 3. The turbidity of circulating water is 50 mg/l, and should not exceed 100 mg/l in the short term. It should not contain oil stains and mechanical impurities. Measures to eliminate algae and stabilize water quality must be taken. 4. This product is suitable for water temperatures not exceeding 60°C. If the water temperature exceeds 60°C, please mention it when ordering so that it can be resolved in material selection. 5. The water pressure of the water inlet pipe of the tower is approximately 2 to 5 meters of water column. Don't make it too high when designing, otherwise water will float if the flow rate is too high. 6. For cooling towers above 150T, the angle of the fan blades can be adjusted, but the angle of each blade must be consistent and the current does not exceed the rated current of the motor. Various types of fans can be reversed for short periods of time to eliminate ice. Therefore, in areas with severe ice, a reversible magnetic starter should be installed. 7. When starting the cooling tower, the water pump must be turned on first and then the fan. It is not allowed to operate the fan without water spraying. | ||||
![]() | ![]() | |||
| ||||
Cross flow fiberglass cooling tower: Definition of terms: In the packing in the tower, water flows from top to bottom, and air flows horizontally from outside the tower to the inside of the tower. The two flow to an orthogonal cooling tower. Tower shape: square. Specifications and models: There are two types of cross-flow cooling towers: BHZ series and HBL series. The BHZ series has low-noise and ultra-low-noise types. The cooling water capacity of a single tower is 80100125150175200m3/h. If the cooling water capacity exceeds 200m3/h, it is an assembled type. In addition to low-noise and ultra-low-noise types, the HBL series also has industrial types with medium and high temperature drops. The cooling water volumes of a single tower are 300, 500 and 700m3/h respectively, and can also be used in parallel. Performance introduction: The BHZ series is characterized by low air flow speed, low noise and low energy consumption. It is suitable for use in places with strict noise requirements. The HBL series is characterized by high air flow velocity, slightly higher noise than the assembly tower, but lower than the counterflow tower, and small footprint. This series of cross-flow cooling towers adopt air inlet from both sides. The fans at the top make the air exchange quality with hot water through the fillers on both sides of the tower. The hot and humid air is then discharged to the outside of the tower. The fillers use point-wave plates with convex points on both sides. The spot wave plate is bonded into a whole through installation to improve rigidity. Since there are bumps on both sides, the chance of water droplets dripping directly is avoided and the effect of forming a water film is improved. The tail of the filler is equipped with water collection measures. The fan adopts low-speed, low-dynamic-pressure airfoil-type fan blades. The power belt reinforced with polyester fiber has low noise, high transmission efficiency and will not slip when exposed to water. Due to the air intake from both sides, the filler is stacked directly from the bottom of the pool to the distribution tank, so the noise is smaller. Precautions for selection and use: 1. When selecting, please know the water volume, inlet water temperature, outlet water temperature and design wet bulb temperature, and determine the model according to the thermal performance curve. 2. In areas where the average temperature in the coldest month is lower than -10℃, please indicate this when ordering so that anti-icing measures can be taken. 3. The turbidity of circulating water is 50mg/l, and should not exceed 100mg/l in the short term. It should not contain oil stains and mechanical impurities. Measures to eliminate algae and stabilize water quality must be taken. 4. This product is suitable for water temperatures not exceeding 65°C. If the water temperature exceeds 65°C, please mention it when ordering so that it can be resolved in material selection. 5. The water inlet pipes are installed on both sides and connected to the water distribution tank. The user should set a valve at the pipe to adjust the flow. 6. The angle of the fan blades should be adjusted uniformly, and the current should not exceed the rated current of the motor, preferably equal to 0.9-0.93 rated current. 7. When starting the cooling tower, the water pump must be turned on first and then the fan. It is not allowed to operate the fan without water spraying. | ![]() | |||
![]() | ||||
![]() | ||||
![]() | ||||
The above information is for reference only. If customers need to make selections, we will provide more detailed instructions and information. |